double

MP-2028M double pump dialysis machine

Product Description

◆ Volume (length× width ×height):
·370mm×340mm ×1570mm
◆ Weight: about 90kg
◆ Power supply voltage: AC220V±10%
·Frequency: 50HZ ~ 60 HZ ·Power: 1500W
◆ Blood pump/spare pump:
·Flux: 15 ~ 340ml/min (Ф 6mm) 20 ~ 460 ml/min (Ф 8mm)
◆ Heparin pump:
·Flux: 0.1ml/h~10ml/h(±5%)
·Precise: 0.1ml/h
·Injector size: 20ml/30ml/50ml
10ml/20ml/30ml
(selectable)
◆ Arterial pressure:
·display scope:-300mmHg~+300mmHg
(±10mmHg)
◆ Venous pressure:
·display scope:-50mmHg~+300mmHg
(±10mmHg)
◆ Dialysate flow:
·300ml/min~800ml/min linearity adjustable
(+10%)
(-5%)
·Temperature:35.0℃~39.0℃
·Resolving rate:0.1℃
·Conductivity:13mS/cm~15.5mS/cm
(±0.1 mS/cm)

◆ UF flow scope: 0~1800ml/h(±30ml/h )
0~4000ml/h(optional)
◆ ISO UF flow scope:0~2000ml/h(±30ml/h)
◆ TMP
·Scope:-100mmHg~+600mmHg
(±20mmHg)
◆ Blood leakage monitor:
over 1ml blood per liter dialysate
(flow:500ml/min)
◆ Blood level monitor: ultrasonic sensor
◆ Air bubble monitor:
Infrared and response threshold value:
Single air bubble of 200 и I exists when
Blood flux is 200ml/min
◆ Inflow pressure:0MPa~0.6MPa
◆ Inflow temperature: 5℃~30℃
◆ Environment temperature: 10℃~30℃,
· Relative humidity≤70%
◆ Rinse/disinfection: chemical disinfection
(citric acid,peracetic acid and oxalic acid)
◆ Hot rinse: 80℃
◆ Back-up power supply: last for 15-30min after electric-cut.
▲ function
1) Can be used in some combination therapy ie. dual plasma adsorption, ascites reinfusion, immune proteins adsorbed and it is quite common used in some special therapy.

2) Can be used in hemoperfusion, seperate plasma exchange and also applies in emergency case.

3) Convenient for patient to change another hand to do treatment and if the length is not long enough, the spare pump can be available for treatment

4) Solution injection/ rehydration.If some patient would like to inject some calcium, Iron etc duing treatment, the spare pump can also be used.

5) If necessary, the spare pump can be adjusted for children’s treatment.

6)Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure ultrafiltration project.

7)Touch screen was equipped and it can show Naand UF profiles;In addition,the functions ie.backup power supply, Kt/V,HC adjustment,single needle,acetate treatment,pyrogen filter port and net connection ect.are optional.

▲ Clinical Application
◆ Hemodialysis Therapy:same as JH-2000
◆ Pure ultrafiltration Therapy: same as JH-2000
◆ Hemoperfusion Therapy:same as JH-2000
◆ Plasma exchange Therapy:same as JH-2000
◆ Na+and UF profiling:
Be applicable for reducing the cases during dialysis treatment such as low/high pressure,muscle convulsion, headache,nausea,vomit ect.

◆ Kt/V function:
·The sufficiency of dialysis can be reflected by Kt/V.(Standard)
◆ HCO3 adjustment function:
·Be applicable for sericous acid toxicosis patient.
Be capable to calibrate the acid toxicosis status according to patient’s state of illness.(Standard)
◆ Backup power-supply:
·It can last for 15-30 minutes after power cut off.
◆ Pyrogen filter port:
Completely filtrating the remained bacteria and endotoxin.(optional)
◆ Net connection:
One computer can audit and control the treatment of maximum 20 units hemodialysis machine (optional)

Reviews

There are no reviews yet.

Be the first to review “MP-2028M double pump dialysis machine”

Your email address will not be published. Required fields are marked *