Product Description
Technical Parameters
▲Extracorporeal circulation system
◆Blood pump flow: 10~620ml/min
◆Blood pump segment Dia.: 6.4 and 8mm adjustable
◆Heparin pump flow scope: 0~10ml/h
◆Syringe: 10ml/20ml/30ml;20ml/30ml/50(optional)
◆Arterial and pressure monitor: -300~+400mmHg(±10mmHg)
◆Venous pressure monitor: -50~+300mmHg(±10mmHg)
◆Air bubble detector: Infrared and ultrasound detection
▲Dialysis system
◆Dialysate flow: 300~800ml/min linearly adjustable(+10%,-5%)
◆Dialysate temperature scope: 35.0~39.0℃
◆Conductivity: 12.3~15.8Ms/cm
◆Na+ adjustment scope: 125~151 mmol/L
◆HCO3- adjustment scope: 24.0~40.0 mmol/L
◆Bicarb Cartridge: Optional
▲Blood leakage detection
◆Method: Photoelectricity detection
▲Ultrafiltration controlling system
◆Ultrafiltration ratio: 0~4000ml/h
◆Pump volume accuracy: ±1%
▲Disinfection and rinse
◆Rinse and heat disinfection(above 90℃)
◆Chemical disinfection: Peracetic acid
◆Heat chemical disinfection: Citric acid
▲Other parameter
◆Dimension: Length*Width*Height:370mm*340mm81450mm
◆Weight: 90Kg
◆Power supply voltage: 100~240V Ac±10% 50~60HZ
◆Power: 1.7KW
◆Back-up battery: At least 30 minutes working after electricity cut
◆Working environment: Temperature: 10~30℃
Relative humidity no higher than 70%
◆Water supply temperature: Temperature: 5~30℃
◆Dialysate formula: Great compatibility be applicable for various concentration ratio formula
◆Pressure: 0.12~0.6Mpa
▲More comprehensive features
◆Combine with Hemodialysis, Hemoperfusion, ISO UF, Hemoperfusion, Plasa Exchange all-in-one
◆Multi-language LCD touch screen with high definition display interface
▲Practicability
◆In-built battery backup to support 30 minutes after power off
◆Disinfection: Rinse,hot disinfection and chemic disinfection .Circulated and closed disinfection system
◆Automatically turn off machine once disinfection process completes
◆Diameter of blood pump can be adjusted to be flexible for adult and child
◆Be applicable for various concentration ratio formula
◆Store treatments information in form of curve profile
◆Full function digital selftest process
◆With visual and auditive alarm,character message shows alarm item and troubleshooting on screen
▲Safety
◆Air bubble monitor: optical and ultrasonic double control, can monitor blood level and accumulate air bubble
◆With safe and sensitive blood leakage monitor device
◆Complete water-way and electric way apart design, individual water-way control system to ensure the security
◆Dialysate temperature with high precision,safety control at 35~39℃
◆Protection from intercross infection,fluid supply loop and return loop is completely divided during disinfection
◆Avoid pollution of whole machine in the case of mis-sucking disinfection liquid
◆Conductivity control and protection: conductivity A,mix. Conductivity ,water outlet conductivity, insure patient’s security
◆Adjustable Na+ curve profile, with multiplicate optional auto-adjust program, can realize individual dialysis and ensure patient’s safety
Reviews